GEA-MK2.1 AND L-PROBE WITH CERAMIC VERSION (CHILLER AS AN OPTION)

 

SPECIAL FEATURES:

  • Oxygen measurement in gas atmospheres
  • simple gas sampling
  • Inexpensive
  • Reliable
  • Insensitive to temperature
  • Insensitive to vibration
  • Easily replaceable
  • Fitting adapted to customers needs
GEA-MK2.1 AND L-PROBE WITH CERAMIC VERSION (CHILLER AS AN OPTION)

FUNCTION

The probe measures the residual oxygen content in a measuring chamber at the end of the measuring gas fitting. The probe signal can be tapped off as a voltage. The probe is heated with a constant voltage. For heating and supplying only power supply approved by MESA may be used.

The quantity of gas passing the probe should be within a range of 20…50 l/h. Too much gas volume can change the highly constant probe temperature, which results in a falsification of the measured value. Every probe includes two constants (K1 and K2). These constants must be entered in the measuring instruments (e.g. intelligent measuring transmitter Carbo48, Carbomat-M, MCON Carbo), if not there will be some measuring faults.

TECHNICAL DATA:

 

Dimension of sensing head: 105 x 290 x 45mm (BxHxD)
Rated length: 400…1100 mm
Connection L-probe: snap closure
Necessary additional parts: NTV44P for heating the L-probe and controlling temperature.
Measuring range: 0…1300 mV
Optional devices • Carbo 15/ 47
• MCon Carbo 16-48
• Carbo 100
• Carbo 1000
• Carbomat-M
• MCON Carbo