DIGITALER TAUPUNKTREGLER DGTP5-AN

[et_pb_section fb_built=“1″ admin_label=“Header“ _builder_version=“4.19.2″ background_color_gradient_direction=“80deg“ background_image=“https://mesa-international.de/wp-content/uploads/2022/02/MESA-Eletronic-GmbH-scaled-2-2.jpg“ parallax=“on“ parallax_method=“off“ positioning=“none“ overflow-x=“hidden“ custom_padding=“0px||0px||false|false“ hover_enabled=“0″ locked=“off“ global_colors_info=“{}“ title_text=“MESA-Eletronic-GmbH-scaled-2″ sticky_enabled=“0″][et_pb_row column_structure=“1_2,1_2″ use_custom_gutter=“on“ gutter_width=“4″ _builder_version=“4.16″ background_size=“contain“ background_position=“bottom_center“ max_width=“1280px“ custom_margin=“-21px|auto|-3px|auto|false|false“ custom_padding=“0px|||||“ global_colors_info=“{}“][et_pb_column type=“1_2″ _builder_version=“4.16″ custom_padding=“40px|||“ custom_padding_tablet=“0vw|||“ global_colors_info=“{}“ custom_padding__hover=“|||“][et_pb_text _builder_version=“4.16″ _module_preset=“default“ header_font=“Archivo|700|||||||“ header_text_align=“left“ header_font_size=“45px“ global_colors_info=“{}“]

DIGITALER TAUPUNKTREGLER DGTP5-AN

 

 

[/et_pb_text][et_pb_testimonial author=“DIGITALER TAUPUNKTREGLER DGTP5-AN“ portrait_url=“https://mesa-international.de/wp-content/uploads/2022/11/DGTP5-AN-300×300-1.png“ quote_icon=“off“ _builder_version=“4.19.2″ _module_preset=“default“ hover_enabled=“0″ border_radii=“on|15px|15px|15px|15px“ global_colors_info=“{}“ title_text=“DGTP5-AN-300×300-1″ sticky_enabled=“0″]

FUNKTION:

Der DGTP5 – AN ist ein emikroprozessorge-steuerter Regler zur Regelung von Schutzgas-erzeugern mit der L-Sonde. Der Regelbereich ist innerhalb der Grenzen von -50,0… +50,0 °Tp frei wählbar. Die L-Sonde kann direkt an den Regler angeschlossen werden, wenn ein NTV 44 zur Versorgung der L-Sonde verwendet wird.Die PID-Reglerparameter werden vom Regler automatisch optimiert (Fuzzy-Logik) und gespeichert.Beim Einsatz als Dreipunktschrittregler ist eine maximale Pulszeit von 2 sec vorprogrammiert, so daß zusätzliche externe Impuls-Pausen-Relais entfallen können.Durch Verwendung eines nichtflüchtigen Speichers bleiben sämtliche Daten und Software-einstellungen auch nach dem Abschalten der Versorgungsspannung erhalten.Der Regler läßt sich über verschiedene Soft-warekonfigurationsebenen auf die jeweilige Anwendung anpassen.

[/et_pb_testimonial][/et_pb_column][et_pb_column type=“1_2″ _builder_version=“4.16″ custom_padding=“|||“ global_colors_info=“{}“ custom_padding__hover=“|||“][et_pb_image src=“https://mesa-international.de/wp-content/uploads/2022/11/DGTP5-AN-300×300-1.png“ title_text=“DGTP5-AN-300×300-1″ _builder_version=“4.19.2″ transform_scale=“113%|113%“ transform_scale_tablet=“116%|116%“ transform_scale_phone=“80%|80%“ transform_scale_last_edited=“off|desktop“ transform_translate_tablet=“30vw|-24vw“ transform_translate_phone=“0vw|-15vw“ transform_translate_last_edited=“off|desktop“ transform_rotate_last_edited=“off|desktop“ transform_skew_last_edited=“off|desktop“ transform_origin_last_edited=“off|desktop“ transform_styles_last_edited=“off|desktop“ position_origin_f=“bottom_center“ width=“100%“ max_width=“480px“ custom_margin=“132px|||||“ animation_direction=“bottom“ hover_enabled=“0″ always_center_on_mobile=“off“ global_colors_info=“{}“ transform_styles__hover_enabled=“on|hover“ transform_scale__hover_enabled=“on|hover“ transform_translate__hover_enabled=“on|desktop“ transform_rotate__hover_enabled=“on|desktop“ transform_skew__hover_enabled=“on|desktop“ transform_origin__hover_enabled=“on|desktop“ transform_scale__hover=“145%|145%“ transform_rotate__hover=“0deg|0deg|13deg“ sticky_enabled=“0″][/et_pb_image][et_pb_button button_url=“https://mesa-international.de/wp-content/uploads/2021/01/Digitaler-universal-regler-DB-DE-v1.0-01-2017-2.pdf“ url_new_window=“on“ button_text=“Datenblatt herunterladen / Download in PDF format“ _builder_version=“4.19.2″ _module_preset=“default“ custom_button=“on“ button_text_size=“14px“ button_text_color=“#ffffff“ button_bg_color=“#e02b20″ button_border_width=“0px“ button_border_radius=“15px“ button_font=“|700|||||||“ custom_margin=“190px|||||“ hover_enabled=“0″ global_colors_info=“{}“ sticky_enabled=“0″][/et_pb_button][/et_pb_column][/et_pb_row][et_pb_row column_structure=“1_2,1_2″ _builder_version=“4.16″ _module_preset=“default“ global_colors_info=“{}“][et_pb_column type=“1_2″ _builder_version=“4.16″ _module_preset=“default“ global_colors_info=“{}“][et_pb_text _builder_version=“4.16″ _module_preset=“default“ header_font=“Archivo|700|||||||“ header_4_font=“Archivo|700|||||||“ header_4_text_color=“#353535″ global_colors_info=“{}“]

TECHNISCHE DATEN

 

 

Bauform: Kunststoffgehäuse zum Schalttafeleinbau
Schutzarten:  
Front: NEMA4 für Einsatz in geschlossenen Räumen (entspricht Schutzart IP66)
Rückseite: Schutzart nach IEC-Norm: IP20
Klemmen: Schutzart nach IEC-Norm: IP20
Abmessungen: 96 x 96 x 115 mm (BxHxT)
Fronttafelausschnitt: 92 x 92 mm (BxH)
Anschluß: Schraubanschluß Drahtquerschnitt max. 2,5 mm
Hilfsspannung: 100…240 Vac, -15 +10 %, 50/60 Hz
Leistungsaufnahme: ca. 16 VA
Klima: Lagerung: -10…+70 °C Betrieb: 0…+50 °C 5…95 % rel. Feuchte, betauungsfrei
Anzeigen: Zwei 4-stellige Siebensegmentanzeigen für PV und SV
Ziffernhöhe: PV = 15 mm rot SV = 11 mm grün
Optionales Zubehör: • MK2.1 + L-Sonde • Netzteil NTV44 • TP
 

[/et_pb_text][/et_pb_column][et_pb_column type=“1_2″ _builder_version=“4.16″ _module_preset=“default“ global_colors_info=“{}“][et_pb_text _builder_version=“4.16″ _module_preset=“default“ header_font=“Archivo|700|||||||“ header_4_font=“Archivo|700|||||||“ header_4_text_color=“#353535″ custom_margin=“3px|||-14px||“ global_colors_info=“{}“]

BESONDERHEITEN:

  •  µP-gesteuerter Regler für mit Fuzzy-Logik für Schutzgaserzeuger
  •  Einsetzbar für Regelstrecken mit Stellmotor (auch ohne Rückmelde- potentiometer) als Dreipunkt-Schrittregler oder als Zweipunktregler
  •  Hohe Genauigkeit (±0,2 %)
  •  Austauschbare Ausgangsbaugruppen
  •  Bis zu 2 frei definierbare Alarmausgänge
  •  Ext. Sollwerteingang 4…20 mA
  •  Modularer Aufbau
  •  Optionaler Istwertausgang 4…20 mA
  •  Serielle Komunikation über RS-232C oder RS422 oder RS-485 und Übertragungsausgang (4…20 mA)