[et_pb_section fb_built=“1″ admin_label=“Header“ _builder_version=“4.19.2″ background_color_gradient_direction=“80deg“ background_image=“https://mesa-international.de/wp-content/uploads/2022/02/MESA-Eletronic-GmbH-scaled-2-2.jpg“ parallax=“on“ parallax_method=“off“ positioning=“none“ overflow-x=“hidden“ custom_padding=“0px||0px||false|false“ hover_enabled=“0″ locked=“off“ global_colors_info=“{}“ title_text=“MESA-Eletronic-GmbH-scaled-2″ sticky_enabled=“0″][et_pb_row column_structure=“1_2,1_2″ use_custom_gutter=“on“ gutter_width=“4″ _builder_version=“4.16″ background_size=“contain“ background_position=“bottom_center“ max_width=“1280px“ custom_margin=“-21px|auto|-3px|auto|false|false“ custom_padding=“0px|||||“ global_colors_info=“{}“][et_pb_column type=“1_2″ _builder_version=“4.16″ custom_padding=“40px|||“ custom_padding_tablet=“0vw|||“ global_colors_info=“{}“ custom_padding__hover=“|||“][et_pb_text _builder_version=“4.16″ _module_preset=“default“ header_font=“Archivo|700|||||||“ header_text_align=“left“ header_font_size=“44px“ global_colors_info=“{}“]

C-PEGEL-REGLER CARBOMAT-M

 

 

[/et_pb_text][et_pb_testimonial author=“C-PEGEL-REGLER CARBOMAT-M“ portrait_url=“https://mesa-international.de/wp-content/uploads/2022/11/Carbomat-M-300×300-1.png“ quote_icon=“off“ _builder_version=“4.19.2″ _module_preset=“default“ hover_enabled=“0″ border_radii=“on|15px|15px|15px|15px“ global_colors_info=“{}“ title_text=“Carbomat-M-300×300-1″ sticky_enabled=“0″]

FUNKTION

Die heute übliche Meßmethode zur Bestimmung des Kohlenstoffgehaltes in Ofenatmosphären ist die indirekte Messung des Sauerstoffgehalts im Ofen mit Zirkoniumoxidsonden. Der CARBOMAT-M bietet für diese Methode besondere Unterstützung.

Der CARBOMAT-M ist ein Einkanalmeß- und Regelsystem zur C-Pegelerrechnung und -regelung in Ofenatmosphären von Wärmebehandlungsanlagen.

 

Über DIP-Schalter auf der Rückseite des Gerätes kann der CARBOMAT-M leicht an vorhandene Anlagen angepaßt werden. Änderungen der Meßwerterfassung, z.B. der Wechsel von Gasanalysatoren auf Sauerstoffsonden, ist problemlos möglich.

Die Sauerstoffmessung durch eine L-Sonde bietet im Härterei-Bereich eine neue preisgünstige Möglichkeit, den Kohlenstoff-gehalt in der Ofenatmosphäre zu bestimmen.

[/et_pb_testimonial][/et_pb_column][et_pb_column type=“1_2″ _builder_version=“4.16″ custom_padding=“|||“ global_colors_info=“{}“ custom_padding__hover=“|||“][et_pb_image src=“https://mesa-international.de/wp-content/uploads/2022/11/Carbomat-M-300×300-1.png“ title_text=“Carbomat-M-300×300-1″ _builder_version=“4.19.2″ transform_scale=“113%|113%“ transform_scale_tablet=“116%|116%“ transform_scale_phone=“80%|80%“ transform_scale_last_edited=“off|desktop“ transform_translate_tablet=“30vw|-24vw“ transform_translate_phone=“0vw|-15vw“ transform_translate_last_edited=“off|desktop“ transform_rotate_last_edited=“off|desktop“ transform_skew_last_edited=“off|desktop“ transform_origin_last_edited=“off|desktop“ transform_styles_last_edited=“off|desktop“ position_origin_f=“bottom_center“ width=“100%“ max_width=“480px“ custom_margin=“132px|||||“ animation_direction=“bottom“ always_center_on_mobile=“off“ global_colors_info=“{}“ transform_styles__hover_enabled=“on|hover“ transform_scale__hover_enabled=“on|hover“ transform_translate__hover_enabled=“on|desktop“ transform_rotate__hover_enabled=“on|desktop“ transform_skew__hover_enabled=“on|desktop“ transform_origin__hover_enabled=“on|desktop“ transform_scale__hover=“145%|145%“ transform_rotate__hover=“0deg|0deg|13deg“][/et_pb_image][et_pb_button button_url=“https://mesa-international.de/wp-content/uploads/2021/01/Carbomat-M-DB-DE-v3.0-02-2017-2.pdf“ url_new_window=“on“ button_text=“Datenblatt herunterladen / Download in PDF format“ _builder_version=“4.19.2″ _module_preset=“default“ custom_button=“on“ button_text_size=“14px“ button_text_color=“#ffffff“ button_bg_color=“#e02b20″ button_border_width=“0px“ button_border_radius=“15px“ button_font=“|700|||||||“ hover_enabled=“0″ global_colors_info=“{}“ sticky_enabled=“0″][/et_pb_button][et_pb_text _builder_version=“4.16″ _module_preset=“default“ header_font=“Archivo|700|||||||“ header_4_font=“Archivo|700|||||||“ header_4_text_color=“#353535″ global_colors_info=“{}“]

FUNKTION

Die heute übliche Meßmethode zur Bestimmung des Kohlenstoffgehaltes in Ofenatmosphären ist die indirekte Messung des Sauerstoffgehalts im Ofen mit Zirkoniumoxidsonden. Der CARBOMAT-M bietet für diese Methode besondere Unterstützung.

Der CARBOMAT-M ist ein Einkanalmeß- und Regelsystem zur C-Pegelerrechnung und -regelung in Ofenatmosphären von Wärmebehandlungsanlagen.

 

Über DIP-Schalter auf der Rückseite des Gerätes kann der CARBOMAT-M leicht an vorhandene Anlagen angepaßt werden. Änderungen der Meßwerterfassung, z.B. der Wechsel von Gasanalysatoren auf Sauerstoffsonden, ist problemlos möglich.

Die Sauerstoffmessung durch eine L-Sonde bietet im Härterei-Bereich eine neue preisgünstige Möglichkeit, den Kohlenstoff-gehalt in der Ofenatmosphäre zu bestimmen.

[/et_pb_text][/et_pb_column][/et_pb_row][et_pb_row column_structure=“1_2,1_2″ _builder_version=“4.16″ _module_preset=“default“ global_colors_info=“{}“][et_pb_column type=“1_2″ _builder_version=“4.16″ _module_preset=“default“ global_colors_info=“{}“][et_pb_text _builder_version=“4.16″ _module_preset=“default“ header_font=“Archivo|700|||||||“ header_4_font=“Archivo|700|||||||“ header_4_text_color=“#353535″ global_colors_info=“{}“]

TECHNICAL DATA

 

Construction: Metal housing for mounting in control panels, in conformance with DIN 40050 Type of protection IP 54, as specified in DIN50050
Dimensions: 144 x 144 x 300 mm (lxwxh)
Auxiliary voltage: 230 Vac ± 10 % 50/60 Hz
Power consumption: About 15 VA
Attention:

If you use L-probe and O2 -probe you can ́t connect an additional Reference junction.

 

  • Thermo couple,typeK or S
  • Reference junction,type K or S (also mixed)
  • Terminal temperature (Pt 100)
  • External set value:analog or through  serial interface

[/et_pb_text][/et_pb_column][et_pb_column type=“1_2″ _builder_version=“4.16″ _module_preset=“default“ global_colors_info=“{}“][et_pb_text _builder_version=“4.16″ _module_preset=“default“ header_font=“Archivo|700|||||||“ header_4_font=“Archivo|700|||||||“ header_4_text_color=“#353535″ custom_margin=“54px|||-14px||“ global_colors_info=“{}“]

Analoge Eingangssignale:
  • O2-Sonde (Zirkoniumoxid), Zellenspannung
    direkt
    oder über Verstärker
  • O2-Sonde und CO-Analysator
  • CO2-Analysator
  • CO2-Analysator und CO-Analysator
  • O2-Sonde und L-Sonde
  • O2-Sonde, L-Sonde und CO-Analysator
  • L-Sonde und CO-Analysator
  • L-Sonde und CO2-Analysator
  • L-Sonde, CO2-Analysator und CO-Analysator
  • L-Sonde und L-Sonde
  • O2-Sonde und O2-Sonde
  • CO2-Analysator und O2-Sonde
Optionales Zubehör:
  • Rel-Box
  • PRL-Box
  • Klemmleistenadapter